InlineLoadCell.com — parallel / independent acquisition planning worksheet Owned planning aid. Not an approved generic wiring diagram. Goal: total force / support distribution / each tendon / one series-path force Mechanical sketch and local external/inertial loads: Number of sensors and individual capacities: Required calibrated force span and smallest useful increment: For each sensor: - Item, revision, serial, approved load direction and mounting - Nominal/calibrated sensitivity per force and zero offset - Input bridge resistance (excitation loading) - Output resistance (combined-output weighting) - Excitation/sense/shield/case diagram and cable arrangement - Calibration association / uncertainty / reference conditions Common excitation, if approved: - Equivalent input resistance and expected supply current - Instrument voltage/current/headroom and approved parallel count - Cable losses, sense arrangement, thermal and fault behavior - Manufacturer-approved matching / trimming / total-system calibration Independent acquisition, if required: - Per-channel rate versus aggregate conversion rate - Simultaneous or multiplexed; channel skew and clock synchronization - Isolation if needed (separate from channel identity) - Timestamps, calibration association, filter, saturation and dropout flags - Controller interface and total latency Acceptance: - Loading distributions and reference forces - Individual readings versus software total, if physically appropriate - Failure/saturation/stale-data response Send the mechanical sketch and acquisition goal to inquiry@inlineloadcell.com.